Line Seiki TC-400 is a multi-function K-type probe thermometer [-160ºC][+1372ºC]

Line Seiki

$49.99
SKU:
292-002
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Sku:292-002

Line Seiki TC-400 is a multi-function K-type probe thermometer [-160°C(-256°F)] - [+1,372°C(+2,502°F)] with Microphone and Manual on CD.

The TC-400 is a multi-function K-type probe thermometer with a wide measuring range of -160°C - +1372°C.  It is a fully functional  thermometer with a sturdy construction for protection.  The front panel keys have a smooth feeling and it can easily be cleaned with a  cloth.  In addition to a the high accuracy of ±0.1% of reading +0.7°C, it has a large view LCD that displays the measured temperature  in °C or °F, Max/Min temperatures in large figure size with a resolution is 0.1°C for temperature measurement of +199°C or less, and  1°C resolution for above +200°C temperatures.  The TC-400 can also store and recall the Max/Min temperatures measured in a  certain period.  Relative temperature measurement is also available when you need to know the increase or decrease of temperature from a reference value.  The °C/°F button allows to user to instantly switch from Celcius and Fahrenheit ranges.  The TC-400 is powered by a 9V battery and it has an Auto-Power off feature to ensure long battery life.  The Hold button ensures the user enough time to record the measurement.  Wide choices of thermocouple probes are available to meet specific application. The TC-400 is truly a versatile and powerful thermometer to address demanding applications.

General Specifications
Sensor Type Type K
Measuring Range -160°C(-256°F) - 1,372°C(+2,502°F)
Resolution 199.9°C (391.8°F) and below: 0.1°C (0.2°F)
200°C (392°F) and above: 1°C (1°F)
Accuracy
(at 25°C(77°F) ±5°C(41°F))
0 - 199.9°C (32°F - 391.8°F): ±0.1% of reading + 0.7°C(1.3°F)
-0.1°C(31.8°F) or less : ±0.2% of reading + 1°C(1.8°F)
200°C(392°F) above : ±0.2% of reading + 1°C(1.8°F)
(at 25°C(77°F) ±5°C(41°F))
Temperature Coefficient ±0.015% of reading + 0.06°C(0.108°F) / °C(1.8°F)
Sampling Time Approx. 1.2sec.
Linearize Method Digital Linearize
Functions °C/°F, Auto-Power Off, Data Hold, Data Record
(Max/Min/Memory), Relative Measurement
Display K
----

Auto Off
HOLD
REL
REC
MAX MIN
MEM
Thermocouple Type
Burn-out
Low Battery
Auto-Power Off
Data Hold
Relative Measurement
Max / Min Data Recording
Max / Min Data Memory
Recorded Memory Data
Operating
Temp. / Humidity
0 - 50°C (32 - 122°F)
0 - 90%RH at 0 - 35°C (32 - 95°F)
Power Supply 006P (9V) Battery
Battery Life Approx. 500Hours
Size / Weight Approx. 166(H) x 68(W) x 35(D)mm, Approx. 200g
Sensor Connector Thermocouple Connector
Accessories Insutruction Manual, 006P battery x 1pc.
Compliance CE and RoHS