X-Rite DTP34L Auto Scan Densitometer.
New open box in Original X-rite box .An essential item for the Photographic and Graphics arts business.
X-RiteColor® DTP34 QuickCal Densitometer is a color measurement instrument that reports
densitometric and dot data.
The instrument is designed to calibrate color output devices including large format printers, proofers,
anddigitally connected color copiers. X-RiteColor® DTP34 QuickCal Densitometer is a “drop-in”
replacement for the X-Rite DTP32 instrument.
Bundle include the following
X-Rite DTP34L
X-Rite DTP34L CD Manual
X-Rite DTP34L Power Supply
X-Rite DTP34L Interface Cables
X-Rite DTP34L Color Reflection Ref.
X-Rite DTP34L Color Management Software.
Instrument Specifications - Preliminary
Measurement Geometry
· Reflection: 0°/45° per ANSI/NAPM 2.17 and ANSI/ISO 5-4
· Multi-sensor array
Measurement Area· 2 mm x 4 mm, 2 mm in the direction of travel. Instrument must set on sample for accurate measurement.
Light Source · Gas pressure @ 2850°K· Lamp file, approx. 1,000,000 scans @ 11” (279.4 mm)
Receiver· Blue enhanced silicon photodiodes
Sample Characteristics
· Patch Size: .400” (10.16 mm) min. in direction of travel by .350” (9 mm) min. wide. 1 mm wide 1.0D contrast space between
patches or .5D min difference between patches.
Measurement Rate· >6” (>154mm)/sec maximum controlled by operator.
System Response· ANSI/ISO Status T
Output· Density, +Dot, -Dot, or Reflectance. Output has x10 capability.
Measurement Range· 0.00D to 2.50D absolute
Linearity· ±0.02D or ±2%, 0 to 2.5D
Repeatability· ±0.01D, 0 to 2.5D
Inter Instrument Agreement· ±0.02D or 2%, 0 to 2.5D
Zero Stability· ±0.01D max
I/O Connection· DB9 socket and USB (future)
Data Interface
· Interface: RS-232 with baud rates from 1200 to 19.2k
· Protocol: RCI commands
Power Requirements· +12v @ 700 mA
Environmental· Operating range: +10°C (50°F) to 35°C (104°F); 30% to 60% RH
· Interface Cable
· AC Adapter (P/N SE30-87)
Optional Accessories
· Mac Serial Adapter (P/N SE108-DB9PA-01)
· 25 Pin Serial Adapter (P/N SE08-231-01)
· Line Cords
For the most recent list of supporting third-party software, see X-RiteColor Enabled Partner literature item L11-031A and L11-031B, or visit
X-Rite DTP34L
X-Rite DTP34L CD Manual
X-Rite DTP34L Power Supply
X-Rite DTP34L Interface Cables
X-Rite DTP34L Color Reflection Ref.
X-Rite DTP34L Color Management Software.
Instrument Specifications - Preliminary
Measurement Geometry
· Reflection: 0°/45° per ANSI/NAPM 2.17 and ANSI/ISO 5-4
· Multi-sensor array
Measurement Area· 2 mm x 4 mm, 2 mm in the direction of travel. Instrument must set on sample for accurate measurement.
Light Source · Gas pressure @ 2850°K· Lamp file, approx. 1,000,000 scans @ 11” (279.4 mm)
Receiver· Blue enhanced silicon photodiodes
Sample Characteristics
· Patch Size: .400” (10.16 mm) min. in direction of travel by .350” (9 mm) min. wide. 1 mm wide 1.0D contrast space between
patches or .5D min difference between patches.
Measurement Rate· >6” (>154mm)/sec maximum controlled by operator.
System Response· ANSI/ISO Status T
Output· Density, +Dot, -Dot, or Reflectance. Output has x10 capability.
Measurement Range· 0.00D to 2.50D absolute
Linearity· ±0.02D or ±2%, 0 to 2.5D
Repeatability· ±0.01D, 0 to 2.5D
Inter Instrument Agreement· ±0.02D or 2%, 0 to 2.5D
Zero Stability· ±0.01D max
I/O Connection· DB9 socket and USB (future)
Data Interface
· Interface: RS-232 with baud rates from 1200 to 19.2k
· Protocol: RCI commands
Power Requirements· +12v @ 700 mA
Environmental· Operating range: +10°C (50°F) to 35°C (104°F); 30% to 60% RH
· Interface Cable
· AC Adapter (P/N SE30-87)
Optional Accessories
· Mac Serial Adapter (P/N SE108-DB9PA-01)
· 25 Pin Serial Adapter (P/N SE08-231-01)
· Line Cords
For the most recent list of supporting third-party software, see X-RiteColor Enabled Partner literature item L11-031A and L11-031B, or visit