X-Rite SpectroEye XRGA Rev. "D" Colorimetry, Color Quality..
Good condition From theworldwideleader in color measurement technology
Bundle include:
SpectroEye unit.
SpectroEye utility software with activation Key.
SpectroEyeManual on CD.
SpectroEyePower Supply.
SpectroEyeCalibration Plaque.
SpectroEye Interface Cable.
SpectroEye Hard Carrying Case.
SpectroEye New Battery Pack.
SpectroEyeManual on CD.
SpectroEyePower Supply.
SpectroEyeCalibration Plaque.
SpectroEye Interface Cable.
SpectroEye Hard Carrying Case.
SpectroEye New Battery Pack.
Functions and Technical Specifications
Colorimetry CIE L*a*b*.
CIE L*C*h (a*b*).
Density.
All Densities.
Print Characteristic.
Contrast.
All Densities.
Print Characteristic.
Contrast.
Dot Gain.
Dot Area.
Trapping.
Reflect. Spectrum.
Best Match.
Auto Function.
Auto Function.
Reject Data.
General Descriptions.
Densitometry Density, All densities (Grey Balance), Dot gain, Dot area, Trapping, Contrast,
Print characteristic, Auto Function
Illumination types D50, D55, D60, D65, D70, D75, A, C, F1...F12
Standard observers 2°, 10°
Density standards ISO Status A, ISO Status E, ISO Status I, ISO Status T, DIN 16536, DIN 16536 NB, SPI
Spectral analysis Holographic diffraction grating
Spectral range 380nm to 730nm
Physical resolution 10nm (internal resolution: 3.3nm)
Measurement geometry 45°/0° ring optic, DIN 5033
Measurement aperture 4.5mm or 3.2 mm (selectable upon order)
Light source Gas-filled tungsten, type A illumination
Physical filters No (incandescent lamp light), Polarized, D65 (Approximated daylight), Optional UV cutoff
Measurement time Approximately 1.5 sec
Measurement range Density DIN 16536: 0.0D–2.5D
Inter-instrument agreement Typical 0.3 ΔE* CIELAB, or 0.15 ΔE CMC(2:1) average based on 12 BCRA tiles (D50, 2°)
Linearity ± 0.01D
Short-term repeatability 0.02 ΔE* CIELAB (D50, 2°), mean value of 10 measurements every 10 seconds on white
Density repeatability Density DIN 16536 (Repeatability ±0.01D): No Filter 0.0D–2.5D, Yellow 0.0D–2.0D Pol Filter 0.0D–2.2D, Yellow 0.0 D–1.8D
Filter wheel Electronic selection of filter
White calibration Automatic on integrated white tile
Instrument check Automatic check of the spectral calibration
Density filter recognition Manual and automatic
Average Averaging for multiple measurement values
Color detection Manual and automatic assignment of samples to references
Serial data interface RS232C with Baud rate: 300 to 57,600
Power supply NiMH battery pack, nom. 7.2V, 1300 mAh
AC adapter requirements 85 VAC to 270 VAC, 47 Hz to 63 Hz
Charge time Approximately 3 hours, automatic disconnection
Charge status Automatic capacity checking and display
Measurements per charge Approximately 3000.
Print characteristic, Auto Function
Illumination types D50, D55, D60, D65, D70, D75, A, C, F1...F12
Standard observers 2°, 10°
Density standards ISO Status A, ISO Status E, ISO Status I, ISO Status T, DIN 16536, DIN 16536 NB, SPI
Spectral analysis Holographic diffraction grating
Spectral range 380nm to 730nm
Physical resolution 10nm (internal resolution: 3.3nm)
Measurement geometry 45°/0° ring optic, DIN 5033
Measurement aperture 4.5mm or 3.2 mm (selectable upon order)
Light source Gas-filled tungsten, type A illumination
Physical filters No (incandescent lamp light), Polarized, D65 (Approximated daylight), Optional UV cutoff
Measurement time Approximately 1.5 sec
Measurement range Density DIN 16536: 0.0D–2.5D
Inter-instrument agreement Typical 0.3 ΔE* CIELAB, or 0.15 ΔE CMC(2:1) average based on 12 BCRA tiles (D50, 2°)
Linearity ± 0.01D
Short-term repeatability 0.02 ΔE* CIELAB (D50, 2°), mean value of 10 measurements every 10 seconds on white
Density repeatability Density DIN 16536 (Repeatability ±0.01D): No Filter 0.0D–2.5D, Yellow 0.0D–2.0D Pol Filter 0.0D–2.2D, Yellow 0.0 D–1.8D
Filter wheel Electronic selection of filter
White calibration Automatic on integrated white tile
Instrument check Automatic check of the spectral calibration
Density filter recognition Manual and automatic
Average Averaging for multiple measurement values
Color detection Manual and automatic assignment of samples to references
Serial data interface RS232C with Baud rate: 300 to 57,600
Power supply NiMH battery pack, nom. 7.2V, 1300 mAh
AC adapter requirements 85 VAC to 270 VAC, 47 Hz to 63 Hz
Charge time Approximately 3 hours, automatic disconnection
Charge status Automatic capacity checking and display
Measurements per charge Approximately 3000.
*We are committed to providing excellent customer serviceand ensuring our customers full satisfaction with their purchases. If the item you receive is different than described in the listing, or if you have concerns or questions, just contact us within 14 days of receiving your shipment to resolve the issue
Disclaimer:We buy and sell pre-owned surplus products and company inventory reductions. We are not representatives or authorized distributors, nor are we affiliated with any manufacturer, brand or product listed. Designated trademarks, brand names and brands appearing in our ads, are the property of their respective owners. Purchaser(s), their agents, assignee's or affiliates assume all responsibility & liability for use, miss-use or application(s) of the item(s) purchased from this seller.