X-Rite i1 Pro 3 PLUS i1Publish Spectrophotometer with ALL i1 Profiler Licenses,
The Standard of Color
Perfection
Designed for imaging professionals who rely on accurate color
for their displays and projectors who want to track and verify monitor and
print quality and who need to capture spot color measurement, the i1Basic Pro 3
Plus is the answer.
With the i1 Pro 3 Plus Publisher, you can quickly and easily create
custom monitor and projector profiles that ensure the colors you view are true,
verify soft proofs and print quality with built-in Quality Assurance (QA)
tools, and easily capture and manage spot colors.
What's Included :
i1Pro 3 Plus spectrophotometer (measurement device),
i1Pro 3 Plus Calibration Plate,
i1Pro 3 Plus Polarizing Filter,
i1Pro 3 Plus Ambient Light measurement head,
i1Pro 3 Plus Monitor Holder,
i1Pro 3 Plus Positioning Target,
i1Pro 3 Plus XL Scanning Ruler,
i1Pro 3 Plus XL Backer Board,
i1Pro 3 Plus USB Cable.
i1Pro 3 Plus Manual.
i1Pro 3 Plus Software.
i1Profiler Software Full Licensed.
- Large
aperture (8mm) with support for high brightness levels (up to 5000nits),
improve emissive measurement, resulting in the best possible calibration
and profiling of monitors and projectors.
- Calibrates
and matches multiple displays, including up to four displays connected to
a single computer as well as unlimited multiple monitors connected to
different computers for consistent color viewing.
- Full
support for the latest video standards, including NTSC, ITU-R-Rec.BT.709
and PAL SECAM broadcast video standards.
- Easy
upgrade to i1Publish software to add complete printer (RGB, CMYK, CMYK +
any four) profiling and quality control functionality, camera profiling
capabilities and transmissive profiling.
- For increased automation, use the optional i1iO automated hands-free chart reader or add an i1iSis 2 automated chart reader for creating printer profiles.
Specifications |
||
Aperture |
Measurement aperture:
8 mm (0.31”) diameter (effective measurement aperture during scanning is depending
on the patch size and measurement speed) |
|
Available Disk Space |
2GB |
|
Calibration |
Manual on external
ceramic white reference (included) |
|
Communication
Interface |
USB 1.1 |
|
Connectivity |
Powered USB port |
|
Dimensions (length,
width, height) |
i1Pro device: 162 mm x
69 mm x 64 mm (6.4” x 2.7” x 2.5”) |
|
Display Resolution |
1024x768 pixels or
higher |
|
Experience Level |
Intermediate to
Advanced |
|
Humidity |
30 to 85% RH
(non-condensing) |
|
Illumination Spot Size |
12 mm (0.47”) |
|
Inter-Instrument
Agreement |
0.3 ∆E00* average, 0.8
∆E00* max. (deviation from X-Rite manufacturing standard at a temperature of
23ºC (73.4ºF) on 12 BCRA tiles (D50, 2º)) |
|
Internet Connection |
Required for software
install, download and automatic update |
|
Languages Supported |
Chinese (Simplified),
English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
|
Light Source |
i1Pro3 Plus LED
Illumination (including UV) |
|
Macintosh |
MacOS X 10.11x, 10.12x
or 10.13x (with latest upgrades installed) |
|
Measurement Conditions |
• M0 - UV included -
ISO 13655:2017 |
|
• M1 - D50 - ISO
13655:2017 |
||
• M2 - UV excluded
Filter - ISO 13655:2017 |
||
• M3 - Polarization -
ISO 13655:2017 |
||
Measurement Frequency
in Scanning Mode |
400 measurements per
second |
|
Measurement Geometry |
45°:0° ring
illumination optics, ISO 13655:2017 |
|
Measurement Spot |
8mm (0.315") |
|
Media Thickness |
1mm or less |
|
Memory |
2GB Minimum |
|
Number of Displays
Supported per Workstation |
Up to 4 |
|
Operating Temperature
Range |
10°C to 35°C |
|
50°F to 95°F |
||
Patch Size |
Minimal Patch Size in
Scanning Mode: 16 x 16 mm (0.63” x 0.63”) (Width x Height) with sensor ruler
20 x 16 mm (0.79” x 0.63”) (Width x Height) without sensor ruler |
|
Photometric Range |
10nm; Sampling
interval 3.5nm |
|
Processor |
MAC: Intel® Core 2 Duo
CPU or better; WINDOWS: Intel® Core 2 Duo or AMD Athlon™ XP or better |
|
Scan Length |
Maximum 515mm
(20.28") |
|
Scanner Target Support |
Yes |
|
Scanning Capability |
Yes |
|
Security |
User must have
Administrator rights to install and uninstall the application |
|
Short Term
Repeatability - White |
0.05 ∆E00 on
white (D50,2°, mean of 10 measurements every 3 seconds on white)5 |
|
Spectral Analyzer |
i1® technology with
built-in wavelengths check; Holographic diffraction grating with 128-pixel
diode array |
|
Spectral Range |
380 - 730 nm |
|
Spectral Reporting |
380 ... 730 nm in 10
nm steps |
|
Storage Temperature
Range |
-20° to 50°C |
|
-4° to 122°F |
||
Supported Profile
Format |
ICC version 2, version
4.3, & iccMax |
|
User Experience |
Choose between a
‘basic’, wizard-driven interface or an ‘advanced’, user-driven interface for
highest level professional results |
|
Video Card |
MAC: Latest drivers
for video card installed |
|
WINDOWS: Latest
drivers for video card installed, dual display support requires either 2
video cards or a dual head video card that supports dual video LUTs being
loaded |
||
Weight |
i1Pro device: 285 g
(10.1 oz) |
|
What's Included? |
i1Pro 3 Plus spectrophotometer (measurement device), calibration plate, polarizing filter, ambient light measurement head, monitor holder, positioning target, XL scanning ruler, XL backer board, USB cable. |
|
Windows |
Windows 7, 8, 8.1, 10
(with latest Service Pack installed) |